SF6 Gas Leak Detection And Analysis

  • GDQH-31H Portable SF6 Gas Recovery Device

    GDQH-31H Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.

    At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV. 

  • GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    GDPDS-341 SF6 Electrical Insulation State Comprehensive Analyzer

    At present, the UHV voltage level of 110KV and above uses SF6 gas-insulated enclosed GIS as the main primary equipment of the substation, the evaluation of GIS internal insulation status is mainly achieved by partial discharge detection method and SF6 gas chemical analysis method at home and abroad. 

  • GDQH-601-50 SF6 Gas Recycling Machine

    GDQH-601-50 SF6 Gas Recycling Machine

    The model GDQH-601-50 is special machine of vacuumizing and filling device. It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.

  • GDSF-311WP SF6 Dew Point and Purity Tester

    GDSF-311WP SF6 Dew Point and Purity Tester

    GDSF-311WP is ideal instrument when it is necessary to test water content and purity of SF6 gas. The core component is DRYCAP series sensors produced by Finland Vaisala company. 

     

  • GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine

    GDQC-55A SF6 Gas Vacuuming and Filling Machine is mainly used for vacuuming and filling SF6 gas insulated electrical equipment in the manufacturing, use and scientific research departments.

    It is suitable for SF6 electrical equipment, GIS manufacturer and research institute.

  • GDJD-3A SF6 Gas Density Relay Calibrator

    GDJD-3A SF6 Gas Density Relay Calibrator

    GDJD-3A SF6 gas Density Relay Calibrator is automatic calibrator, which uses embedded microprocessor to proceed performance calibration for all kinds of SF6 gas density relay. 

  • GDSF-411CPD SF6 Gas Comprehensive Analyzer

    GDSF-411CPD SF6 Gas Comprehensive Analyzer

    GDSF-411CPD SF6 gas comprehensive analyzer is a portable device designed to measure SF6 gas dew point, purity and decomposition product.

  • GDQH-31W Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device

    GDQH-31W Portable SF6 Gas Recovery Device (MINI) is used in the manufacturing plant of SF6 gas insulated electrical equipment and operation & scientific research departments to fill electrical equipment with SF6 gas and recover SF6 gas from electrical appliances used or tested.

    At the same time, it is purified and compressed and stored in the storage tank. Suitable for ring network distribution network below 50kV. 

      

     

     

     

  • GDIR-1000L SF6 Gas Infrared Imaging Leak Detector

    GDIR-1000L SF6 Gas Infrared Imaging Leak Detector

    GDIR-1000L SF6 Gas Infrared Imaging Leak Detector  is a highly technical instrument which is independently developed by our company and has independent intellectual property rights.

  • GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM SF6 Gas Dew Point Tester (Chilled Mirror Method)

    GDP-8000CM Portable Chilled Mirror SF6 Gas Dew Point Tester is specially designed for SF6 gas micro moisture detection used in the whole temperature zone of the power industry, which is based on Stryn refrigeration and chilled mirror measuring principle.

  • GDLD-313IR SF6 Gas Leak Detector

    GDLD-313IR SF6 Gas Leak Detector

    GDLD-313IR SF6 Gas Leak Detector is updated model, which is infrared red type leak detector (NDIR technology). It is LCD display and real-time shows SF6 concentration. It rapidly detects SF6 breaker, GIS leakage point and yearly leakage rate qualitatively and quantitatively. It’s a good device suitable for power supply department, installation and overhaul unit, power test institute.

    The smart quick intelligent test system is used, the software registering number 1010215, trademark registering number 14684781.

  • GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 Gas Leakage Detector

    GDWG-III SF6 gas leakage detector, with non-dispersed infrared (NDIR) technology, is mainly used to pinpoint and measure SF6 leakage on GIS and refilling equipment within power industry. 

     